Creating a primary suite: expand or reconfigure? 2 floor plans compared

By Clara AJMAR, Interior Design & Landscape Specialist (updated October 2026)

24 m² existing, 2 ways to create a true primary suite: either reconfigure without expanding, or gain floor area to improve the walk-in closet, the home office and the bathroom with its toilet.

Creating a primary suite does not necessarily mean adding on to the house. In this project, the existing space already offers about 24.4 m² (263 sq ft) to work with. Two scenarios were therefore compared: keeping this floor area and reconfiguring it, or expanding the space to reach 29.2 m² (314 sq ft) to give more room to the bathroom, the toilet, the walk-in closet and the home office.

The point of this comparison is to avoid treating an addition as the automatic answer. Before adding square footage, you need to understand what the existing space can already do, then measure what the extra floor area really brings to everyday life.

How do you assess the potential of the existing space to create a primary suite?

Before drawing an addition, the first step is to read the existing conditions carefully. Here, the existing space includes two bedroom areas, a covered terrace, a bathroom with a shower and a large vanity, a separate toilet with a boxed-in chase, and an interior hallway that connects the different spaces.

Existing floor plan before creating a primary suite, with two bedrooms, covered terrace, bathroom, toilet and hallway
Existing conditions: 1. Bedroom with sofa bed · 2. Bedroom with bed and closet or storage · 3. Covered terrace · 4. Bathroom with shower and large vanity · 5. Toilet with boxed-in chase · 6. Interior hallway.

How much floor area do you need for a primary suite with a walk-in closet and bathroom?

There is no single floor area that works for every project. The shape of the rooms, the access points and the functions you want to include matter as much as the square footage. In this case, the existing 24.4 m² is already enough to study a layout with a bedroom, a walk-in closet, a home office and a bathroom.

A comparable project shows how to lay out a 25 m² (270 sq ft) primary suite with a walk-in closet, bathroom and home office. The similar floor area makes it easy to compare two different ways of organizing a similar program.

How do you fit a bedroom, a walk-in closet and a home office into 24.4 m²?

The first challenge is to prioritize the functions. The bed needs a comfortable spot, but it cannot take up all the available space. The walk-in closet and the desk must be part of the overall design to avoid a pile-up of freestanding furniture and to keep clear circulation.

Where should the bathroom and toilet go in an existing primary suite?

The existing layout already has a separate bathroom and toilet. The two scenarios use this arrangement differently: the plan without an addition keeps a more compact bathroom, while the expanded plan devotes more floor area to it and brings the toilet inside.

How do you optimize circulation in a primary suite?

Part of the existing floor area is taken up by an interior hallway. Reworking the plan therefore also means checking whether this circulation is still needed as it is, or whether it can be absorbed more efficiently into the new layout of the suite.

Can you create a primary suite without adding on to the house?

In this project, yes: a complete layout is drawn within the existing 24.4 m². It does not offer exactly the same level of comfort as the expanded version, but it shows how far you can go before adding floor area.

Plan 1: reconfiguring 24.4 m² without expanding

The first strategy is to work only within the existing envelope. The goal is to redistribute the 24.4 m² to create a bedroom with a home office area, a walk-in closet and a small bathroom.

In the zoning plan, the walk-in closet is a clearly defined zone. The bedroom stays flexible enough to also include a desk, so the main room is not used for sleeping only.

The bathroom is deliberately more compact. This scenario shows what you can achieve by redistributing the functions first, without creating extra square footage.

This approach echoes another project where we studied how to turn a small garage into a primary suite without an addition. The floor area and the context are different, but the starting question is the same: how far can you go with what is already there?

Plan 2: expanding to 29.2 m² for a more complete primary suite

The second plan takes a different approach. The interior floor area grows to about 29.2 m², compared with 24.4 m² in the version without an addition.

That represents about 5 m² (54 sq ft) of additional interior floor area, excluding masonry walls and insulation linings. This detail matters: the figure is used here to compare proportions and uses shown on the plan, not to describe the total footprint of the new construction.

The bedroom fits a large bed. A generous walk-in closet is created and paired with a home office area. The addition is mainly used to enlarge the bathroom and bring the toilet into this new layout.

Two zoning plans compared for creating a primary suite with or without an addition
Two design scenarios: left plan ①, expanded version (Plan 2 in this article): 1. Bedroom with large bed · 2. Large walk-in closet with home office · 3. Addition housing the bathroom and toilet. Right plan ②, version without an addition (Plan 1 in this article): 4. Walk-in closet · 5. Small bathroom · 6. Bedroom with home office.

So the real question is less about going from 24.4 to 29.2 m² than about understanding what those extra square meters actually improve: the size of the walk-in closet, the home office and, above all, the bathroom.

Expand or reconfigure: how do the two floor plans differ?

Both plans meet the same goal, but they do not use the floor area in the same way. The 24.4 m² scenario focuses on optimizing the existing space. The 29.2 m² scenario uses about 5 m² of additional interior floor area to give more room to the walk-in closet and, above all, to the bathroom with its toilet.

Professional tip
Comparing the plans against the same criteria keeps you from concluding too quickly that the bigger option is automatically the better one. Look at where the square footage is really gained, which functions become more comfortable and what extra work is needed to get there.

Another project follows a similar approach by studying how to enclose a loggia to expand a primary suite. Here again, the question is not just about gaining floor area, but about checking what it really brings to the plan.

How do you compare two primary suite scenarios with a clear method?

The comparison becomes clearer when you do not look at the final floor area alone. In this project, several criteria can be set side by side: space given to the bed, closet capacity, room for a desk, bathroom size, whether the toilet is inside the suite, and the quality of circulation.

This method turns two drawings into real decision-making tools. The scenario without an addition shows how far the existing space can be optimized. The expanded scenario then shows what the extra floor area improves in practice.

This other ArchiWorking video uses exactly the same comparison logic in a different context: two scenarios are drawn to convert a garage into a primary suite.

Which option should you choose based on daily use, floor area and scope of work?

The plan without an addition is about optimization: keep the existing envelope and focus the work on reorganizing the interior. It creates a bedroom with a home office, a walk-in closet and a bathroom within the available 24.4 m².

The expanded plan answers a different priority. The 29.2 m² gives more room to the walk-in closet and the home office, but above all it creates a more generous bathroom that includes the toilet.

ArchiWorking field experience
Drawing both scenarios is not necessarily about choosing one right away. The comparison first helps identify what truly justifies an addition and what can already be achieved by better reorganizing the existing space.

Here, the request came from a retired couple who often host their grandchildren. The 10.2 m² (110 sq ft) terrace, already covered and enclosed, made it possible to expand and add a toilet within easy reach when coming back from the pool, at the cost of more work and extra permits. Without expanding, we kept a 1.20 × 2.35 m bathroom and a 1.40 m desk, but no toilet inside the suite.

Explore more real projects, floor plan studies and layout comparisons on the ArchiWorking YouTube channel.

Clara AJMAR, interior designer and landscape architect (DPLG)

Frequently asked questions about creating a primary suite

Can you create a primary suite without adding on?

Yes, when the existing floor area and layout allow it. In this project, the first plan works only within the existing 24.4 m² to fit a bedroom with a home office, a walk-in closet and a small bathroom.

What can an addition bring to a primary suite?

In this specific project, going from 24.4 to 29.2 m² represents about 5 m² of additional interior floor area, excluding masonry walls and insulation linings. This gain mainly improves the walk-in closet, the home office and the bathroom with its toilet.

Should you always choose the plan with the most floor area?

No. The comparison should focus on which uses are really improved and on the scope of work required. A few extra square meters are only worth it if they solve a constraint or make daily life noticeably better.

How do you compare two primary suite floor plans?

It helps to compare both plans against the same criteria: bedroom size, storage, walk-in closet, home office, bathroom, toilet, circulation and how much the existing space has to be transformed.